Publish Time: 2026-11-20 Origin: Site
One panel uses a thicker absorbing layer. Another uses a thinner layer held away from the wall. Their NRC ratings can match, yet they may absorb different amounts at the frequencies you hear. To compare sound absorbing panels, start with the material, then look at its thickness and how it will be mounted.
Start with the full installation, from the finished face back to the wall. A single number on a product sheet can describe the absorbing layer, the finished panel, or the entire mounted assembly. Ask which dimension or material the supplier is quoting.
What to check | What it describes | Why it matters |
|---|---|---|
Core density | The mass of the absorbing material per unit of volume | Helps you compare versions of the same material |
Absorber thickness | The depth of the material that absorbs sound | Helps explain why absorption changes across frequencies |
Air gap | The open space between the panel and the wall | Can change absorption in some frequency bands |
Total installed depth | How far the finished assembly projects from the wall | Tells you whether the tested setup fits the room |
A wood slat panel illustrates why these details matter. Its overall thickness can include the slats and felt backing. Ask for a section drawing that shows the thickness of the felt, the depth of the slats, and any space behind the panel. This gives you the dimensions you need before comparing material density.
In a porous absorber, sound causes air to move through small openings in the material. The material resists that movement and dissipates some of the sound energy. Airflow resistivity describes how strongly the material resists that airflow. Density can influence it, alongside fiber size and how the fibers are arranged. Two materials of similar density can therefore absorb sound differently.
Compare density within the same product family. If a supplier offers two densities of the same PET panel, request data for versions of the same thickness and mounting. Then check whether the difference appears in the bands you need. A comparison between PET and mineral wool also involves differences in fiber structure and construction.
Check what the stated density refers to. A wood face, fabric cover, or frame can add weight to the finished product. Ask for the density of the absorbing core if you need to compare materials. Use the absorption curve of the finished product to judge how the supplied assembly performs.
Once you’ve identified the absorbing material, compare what happens when you use more of it. A thicker porous layer can extend useful absorption into lower frequencies. The clearest comparison holds the material and mounting as consistent as possible. Then look for a change in the bands your project needs.
For a meeting room with lingering speech, compare the bands relevant to conversation. A shallow panel may suit the project if its tested absorption and proposed coverage meet the room’s needs. Check how far it can project near door swings, trim, and furniture.
For a studio with boomy playback, identify the affected range before specifying thickness. Play the same passage from several listening positions. If the problem changes sharply across seats, check speaker and seat placement as part of the diagnosis. When comparing absorbers, ask for results around the affected frequencies, including 125 Hz if it is relevant and available.
An air gap moves a porous absorber away from the wall. This changes the sound field at the material and can improve absorption in some frequency bands. The gap adds installed depth, so check how much space you have before deciding between a thicker absorber and a thinner panel on spacers.
If the design requires direct mounting, ask for results for that installation.
If battens or spacers are an option, compare the same panel with and without the proposed gap, where the supplier has both sets of data.
If the cavity contains infill, check the material, thickness, and remaining air space shown in the test setup.
Tip: Ask suppliers to show cavity depth and total projection on the same drawing, then price the supports needed to reproduce it.
Autex’s published Cube data illustrates how thickness and mounting can change the result. These figures apply to the listed configurations. Where a row says “no gap listed,” that reflects how the configuration is presented in the source.
Published Cube configuration | 125 Hz | 250 Hz | 500 Hz | NRC |
|---|---|---|---|---|
12 mm panel, no gap listed | 0.05 | 0.10 | 0.30 | 0.45 |
12 mm panel with 25 mm air gap | 0.05 | 0.30 | 0.60 | 0.70 |
24 mm panel, no gap listed | 0.05 | 0.20 | 0.60 | 0.70 |
24 mm panel with 25 mm air gap | 0.15 | 0.40 | 0.85 | 0.80 |
Read across the table for the frequencies you care about. Moving from the 12 mm panel to the 24 mm panel in the rows with no gap listed raises the value at 500 Hz from 0.30 to 0.60. The value at 125 Hz stays at 0.05. If 125 Hz is your main concern, that thickness change offers little help in this specific comparison.
Now compare the two configurations rated NRC 0.70. They both list 0.60 at 500 Hz. At 250 Hz, the 12 mm panel with a gap lists 0.30, compared with 0.20 for the 24 mm panel. The thinner product uses 37 mm of nominal installed depth once its gap is included. If a walkway or door limits projection, that extra depth may decide which setup you can use.
Give each supplier the same sound problem, available depth, and treatment area. Use those constraints to compare what the buyer will receive and what the installer will build.
Identify the target bands. Describe the sound you want to control and share any relevant room measurements.
Set a depth limit. Measure from the wall to the maximum finished projection. Account for the panel, supports, and cavity.
Match the quote to the test. Check the model, absorbing thickness, facing, backing, and mounting. Confirm whether the test used an open or filled cavity.
Compare performance and installed price. Use NRC to narrow the options, then compare the target bands. Include the hardware and labor needed to match the tested setup.
Example: A practice room has a narrow walkway opposite a glass wall. A supplier’s highest rating uses battens that would project into the walkway. Ask for test data and pricing for a shallower setup. Then check whether it offers enough absorption in the bands your room needs.
If a supplier proposes a different density, thickness, or mount after quoting, check whether the available test report covers the change. Record the chosen panel and mounting detail together so the installer can reproduce the assembly you evaluated.
Use density to describe the material. Check how thickness and air gaps affect absorption in the frequencies you need.
Match the tested assembly to your available depth. Specify the panel and mounting together before ordering.
Shanghai ColorBo Industrial Development Co., Ltd. offers PET, fabric, and wood slat panels for different layouts and finishes.
A: Density alone gives you limited information about how a panel will absorb sound. Fiber size, structure, and airflow resistance also play a role. Compare sound absorbing panels of similar thickness and mounting, then check the measured results in the frequency bands you need.
A: Choose thickness based on the sound you want to control and the depth available. Compare frequency-band results for the exact mounting you plan to use. If a deeper panel takes up valuable room space, check whether its measured improvement occurs in the bands that matter to you.
A: An air gap is worth considering when the tested setup shows better results in your target bands. Compare the same panel with and without a gap, when both sets of data are available. Include the spacers or battens when checking how far the assembly will project.
A: It can if the tested results meet the same requirements and the assembly fits. Compare the individual frequency bands and total installed depth. Two configurations can share the same NRC while offering different absorption at 250 Hz or taking up different amounts of space.